Troubleshooting Damage From Ice Dams

1/11/2022 (Permalink)

Ice Dams are thick ridges of solid ice that build up along the eaves on a roof.  Ice damns can lead to Dams can tear off gutters, loosen shingles, and cause water to back up and pour into your house.

Getting rid of ice dams for good is simple, in principle: Just keep the entire roof the same temperature as the eaves. You do that by increasing ventilation, adding insulation, and sealing off every possible air leak that might warm the underside of the roof.  Possible troubleshooting methods include:

  1. Ventilate Eaves And Ridge. A ridge vent paired with continuous soffit vents circulates cold air under the entire roof. Both ridge and soffit vents should have the same size openings and provide at least 1 square foot of opening for every 300 square feet of attic floor. Place baffles at the eaves to maintain a clear path for the airflow from the soffit vents.
  2. Cap the Hatch. An unsealed attic hatch or whole-house fan is a massive opening for heat to escape. Cover them with weather stripped caps made from foil-faced foam board held together with aluminum tape.
  3. Exhaust to the Outside. Make sure that the ducts connected to the kitchen, bathroom, and dryer vents all lead outdoors through either the roof or walls, but never through the soffit.
  4. Add Insulation. More insulation on the attic floor keeps the heat where it belongs. To find how much insulation your attic needs, check with your local building department.
  5. Install Sealed Can Lights. Old-style recessed lights give off great plumes of heat and can’t be insulated without creating a fire hazard. Replace them with sealed “IC” fixtures, which can be covered with insulation.
  6. Flash Around Chimneys. Bridge the gap between the chimney and house framing with L-shaped steel flashing held in place with unbroken beads of a fire-stop sealant. Using canned spray foam or insulation isn’t fire safe.
  7. Seal and Insulate Ducts. Spread fiber-reinforced mastic on the joints of HVAC ducts and exhaust ducts. Cover them entirely with R-5 or R-6 foil-faced fiberglass.
  8. Caulk Penetrations. Seal around electrical cables and vent pipes with a fire-stop sealant. Also, look for any spots where the light shines up from below or the insulation is stained black by the dirt from passing air.